- Figure 1 – GWeld Interface
Purpose:
*CONSTRAINED_GENERALIZED_WELD has many variants in LS-DYNA, but this interface is specifically for showing, creating, modifying, and deleting *CONSTRAINED_GENERALIZED_WELD_SPOT cards. Failure parameters can be set as desired and used for the welds being created. Also these parameters can be modified as necessary for each weld.
Controls:
Show – Show existing *CONSTRAINED_GENERALIZED_WELD_SPOT entities
Create – Create new *CONSTRAINED_GENERALIZED_WELD_SPOT entities
Modify – Modify existing *CONSTRAINED_GENERALIZED_WELD_SPOT entities
Delete – Delete existing *CONSTRAINED_GENERALIZED_WELD_SPOT entities
For Show, Modify, and Delete, the Entity Operation Interface is displayed in the secondary controls area. For Create, the General Selection Interface is displayed in the secondary controls area.
- Label – Select label type
Click to view and modify weld parameters
- CID: Enter coordinate system ID
- FILTER:Enter number of force vectors saved for filtering
- WINDOW: Enter time window for filtering
- NPR: Enter number of individual nodal pairs
- NPRT:Print option for RBDOUT (see LS-DYNA keyword manual for details)
- TFAIL: Enter failure time for constraint set
- EPSF: Enter effective plastic strain at failure
- SN: Enter normal force at failure, only for brittle failures
- SS: Enter shear force at failure, only for brittle failures
- N: Enter exponent for normal force, only for brittle failures
- M: Enter exponent for shear force, only for brittle failures
- WID – Enter genweld optional ID
- NSID – Enter Node Set ID
Select all *CONSTRAINED_GENERALIZED_WELD_SPOT entities
Deselect all *CONSTRAINED_GENERALIZED_WELD_SPOT entities
Reverse selection
Select all entities within the selected range (Only applies when there are 20+ entities)
Apply entries for creation/modification or selections for deletion
Exit Constrained Generalized Weld Spot Data interface
- Click item from list to select