To prevent instabilities resulting from shooting nodes, LS-DYNA uses a so-called “shooting node logic” routine, which is activated via SNLOG=0 (default). “Shooting…
READ MOREThe SMOOTH option for contact uses a surface fitting algorithm so that the contact can be calculated on the surface, rather than…
READ MORESOFT = 1 option The contact formulation invoked by setting Soft=1 on optional card A of *CONTACT is not so radical a…
READ MOREConstraint-based / Penalty-based Contacts Tied contacts fall into 2 major categories: constraint-based and penalty-based. Those with TIEBREAK, OFFSET, or BEAM_OFFSETin…
READ MORELike *CONTACT_AUTOMATIC_SINGLE_SURFACE, *CONTACT_AUTOMATIC_GENERAL is a single surface contact, that is, the contact is defined wholly by the slave side. Both contact types consider…
READ MOREIGNORE=1 At any point during the simulation, if a node is suddenly found to be below the surface (say, it…
READ MORE