Release notes up to v4.0

Relase notes for WorldSID v4.0

+ Geometric update of neck bracket, which can now also be adjusted in the positioning simulation

 

     WSID_v3.5                                         WSID_v4.0

Modification_01

+ Update of 2D IR-TRACC geometry. Due to this, the physical stop angles are captured more accurately

 

        WSID_v3.5                                             WSID_v4.0

Modification_02

+ Battery in thorax has been changed to some smaller mass replacements

 

              WSID_v3.5                        WSID_v4.0

 Modification_03

 

+ Arm validation has been improved. In some Rib component test it is observer that WSID v3.5 seams to have a very soft arm behavior in bending. Due to this the behavior of the arm is compared to video evaluations and improved. In the following a rib component test with arm is shown for both versions of WorldSID:

 

          WSID_v3.5                                                WSID_v4.0

 RibTest_01

 RibTest_02

 RibTest_03

 RibTest_04

RibTest_05 

 RibTest_06

 

 

Item Node ID                  Label Available Components
Shoulder rib 10751 shoulder rib deformation
Local X/Y/Z
x-, y-, z-displacement
1. Thorax rib 10752 1 thorax rib deformation
Local X/Y/Z
x-, y-, z-displacement
2. Thorax rib 10753 2 thorax rib deformation
Local X/Y/Z
x-, y-, z-displacement
3. Thorax rib 10754 3 thorax rib deformation
Local X/Y/Z
x-, y-, z-displacement
1. Abdomen rib 10755 1 abdomen rib deformation
Local X/Y/Z
x-, y-, z-displacement
2. Abdomen rib 10756 2 abdomen rib deformation
Local X/Y/Z
x-, y-, z-displacement

 

 

Parameter name Joint
 sfarmx Scale factor arms local x-rotation
 sfarmy Scale factor arm local y-rotation
 sffemr Scale factor upper legs all directions
 sfknee Scale factor knees
 sfankl Scale factor ankle joints all directions

Relase notes for WorldSID v3.5

+ Initial Arm position is set to EuroNCAP position

>> EuroNCAP Oblique Pole Side Impact Testing Protocol (Version 7.0 of June 2014):

5.3.6.1: Place both arms at the first detent downward of the most upward detent that corresponds to a differential angle of 32° between rib angle sensor and the arm angle.

>> Rib angle sensor is 0° sensor if the 2. and 3. thorax ribs are horizontal

>> Arm must then be positioned 32° downwards from the horizontal

>> Tree file is adjusted to show -32° for arm position

>> Outer shape of v3.5 compared to v3.0 has not changed, except for the arm position

+ One additional node has been defined NID 10000. This node has the same co-ordinates as the node ID 10501 which is located on the H-Point. This has been done due to positioning issues faced with previous versions.

 

+ Due to the strange behavior of the Jacket in WSID v3.0, the jacket has been changed:

>> The solid material of the jacket has been improved

>> The outer shell layer has been changed from *MAT_NULL to *MAT_FABRIC with physical tension stiffness

Relase notes for WorldSID v3.0

+ The complete neoprene suit of the WorldSID is now meshed with solids

+ Arm foam and rubber mesh is now disconnected from arm bone

+ 2D IR-TRACCs including new stop angles (SBL-E1)

+ New sacrum box recorder in the pelvis (SBL-E1)

+ The arm component was improved

+ Neck model improvement

+ Shoulder rib component test in z-direction

+ The nitinol material of the rib bands now uses *MAT_SHAPE_MEMORY. This should increase the overall stability and robustness of the dummy model.

+ Some load cell orientations were corrected to match the SAE standard: upper and lower neck, shoulder, lumbar spine, pubic, sacro iliac and femur load cells

+ Improvement of the pelvis flesh model to avoid high hourglass energies

+ Improvement of the whole dummy definition to reduce time step dependency of the model

+ Parameter tpref to switch on/off the foam reference geometry of the thorax pad

+ More robustness against variation of time step size

+ New positioning procedure

Relase notes for WorldSID v2.0

Relase notes for WorldSID v1.0