Home » Knowledge Base » LS-Prepost » Tutorials » Extended Tutorials » Tutorial 6 » Tutorial 6: Page 9
- 9. Create seatbelt to dummy contacts (for more details see Tutorial 1)
- go to Page 3: *Contact
- select [*]AUTOMATIC_SURFACE_TO_SURFACE (2) from the list
- click Edit
- click NewID in the KEYWORD INPUT popup form
- enter TITLE: belt to dummy contact
- select SSTYP=3
- select MSTYP=2
- click the SSID link button (dot)
- select “1738” in Link PART Dialog
- click Done in Link SET Dialog
- click the MSID link button (dot)
- select “1000013 pelvic and torso” in Link SET Dialog
- click Done in Link SET Dialog
- enter FS=FD=0.2
- enter VDC=BT=0.0
- enter SFS=SFM=1.0
- activate
A
- select SOFT=2
- click Accept
- click Done